Service – Locomotives (All Requests)

Railroad:       Road #:

Service Type: Electrical       Status: Closed      

Issue Details
Reported: 02/11/18       By: John Eilers

Problem Description:

hesitates through truckee yard switches. Would suggest fitting a better decoder with back emf to get the loco through switches at slow speeds.


Checked Out:
02/11/18       By: John Eilers  

Service Information
Serviced: 02/11/18       By: John Eilers

Solution Description/Service Details:

JohnE:
This is a duplicate of another filed service request.

As noted in the inventory, this is not a club engine.
A 6 axle locomotive should never need EMF to simply go through a yard ladder. This points to a power pick up problem. Likely due to the pickup wires being connected with clips rather than soldered.